中文 English
You are here: Tutorials > Cavitation Over an Orifice > Post processing > Validation

Validation

The coefficient of discharge (Cd) is calculated as follows:

11.2  

where,

A Area of Orifice(m2): 5.02655E-05
m. Outlet Mass Flow Rate (kg/s): 0.68
Density (kg/m3): 1000
P1 Inlet Pressure Pa: 250000
P2 Outlet Pressure Pa: 95000

The comparison of the coefficient of discharge from experiments and Simerics-MP+ are as follows:

  Experiment Simerics MP+
Coefficient of discharge 0.78 0.768

Reference: W.H. Nurick, “Orifice Cavitation and Its Effects on Spray Mixing”, Journal of Fluids Engineering, Vol 98, pp. 681-687, 1976.

 

Copyright © 2023 Simerics Inc.,